Capillaries and connections depend on which system is installed.
NOTA
As you move to smaller-volume, high-efficiency columns, you will want to use narrow id tubing, as opposed to the wider id tubing used for conventional HPLC instruments.
NOTA
Agilent capillaries are color-coded for quick identification, see At-a-Glance Details About Agilent Capillaries.
p/n | From | To |
|---|---|---|
G7120-60007 (Conjunto da parte superior da garrafa, longo (1730 mm)) | Solvent Bottle | Infinity III Pump |
5500-1246 (Capillary ST 0.17 mm x 500 mm SI/SI) | Pump | Sampler |
5500-1217 (Capillary, ST, 0.17 mm x 900 mm SI/SX) | Pump | Vialsampler with ICC |
5500-1246 (Capillary ST 0.17 mm x 500 mm SI/SI) | Multisampler | MCT Valve/Heat Exchanger |
5500-1252 (Capillary, ST, 0.17 mm x 400 mm SL/SL) | Vialsampler | MCT Valve/Heat Exchanger |
5500-1240 (Capillary ST 0.17 mm x 105 mm SL/SL) | Vialsampler | ICC Heat Exchanger |
5500-1250 (Capillary, ST, 0.17 mm x 120 mm SL/SL, long socket) | ICC Heat Exchanger | Column |
5500-1193 (Capilar de conexão InfinityLab Quick Turn ST 0,17 mm x 105 mm, soquete longo) | MCT Heat Exchanger | Column |
5500-1191 (Capilar de conexão InfinityLab Quick Turn ST 0,12 mm x 280 mm, soquete longo) | Column/MCT Valve | Detector |
5062-8535 (Waste accessory kit (Flow Cell to waste)) | VWD | Waste |
5062-2462 (Tube PTFE 0.7 mm x 5 m, 1.6 mm od) | DAD/FLD | Waste |
G5664-68712 (Analytical tubing kit 0.25 mm i.d. PTFE-ESD) | Detector | Fraction Collector |
p/n | From | To |
|---|---|---|
G7120-60007 (Conjunto da parte superior da garrafa, longo (1730 mm)) | Solvent Bottle | Infinity III Pump |
5500-1245 (Capillary ST 0.17 mm x 400 mm SI/SI) | Pump | Sampler |
5500-1217 (Capillary, ST, 0.17 mm x 900 mm SI/SX) | Pump | Vialsampler with ICC |
5500-1157 (Capillary ST 0.12 mm x 500 mm SL/S) | Multisampler | MCT Valve/Heat Exchanger |
5500-1251 (Capillary ST 0.12 mm x 400 mm SL/SL) | Vialsampler | MCT Valve/Heat Exchanger |
5500-1238 (Capillary ST 0.12 mm x 105 mm SL/SL) | Vialsampler | ICC Heat Exchanger |
5500-1249 (Capillary ST 0.12 mm x 120 mm SL/SL, long socket) | ICC Heat Exchanger | Column |
5500-1201 (Capillary ST 0.12 mm x 105 mm SL) | MCT Heat Exchanger | Column |
5500-1191 (Capilar de conexão InfinityLab Quick Turn ST 0,12 mm x 280 mm, soquete longo) | Column/MCT Valve | Detector |
5062-8535 (Waste accessory kit (Flow Cell to waste)) | VWD | Waste |
5062-2462 (Tube PTFE 0.7 mm x 5 m, 1.6 mm od) | DAD/FLD | Waste |
G5664-68712 (Analytical tubing kit 0.25 mm i.d. PTFE-ESD) | Detector | Fraction Collector |
p/n | From | To |
|---|---|---|
G7120-60007 (Conjunto da parte superior da garrafa, longo (1730 mm)) | Solvent Bottle | Infinity III Pump |
5500-1264 (Capillary Ti 0.17 mm x 500 mm, SL/SLV) | Pump | Multisampler |
G5667-81005 (Capillary PK/ST 0.17 mm x 500 mm, RLO/RLO (Bio-inert)) | Multisampler | MCT |
5067-4741 (União ZDV (bio-inert)) | Capillary | Bio-inert Heat Exchanger |
G7116-60041 (Trocador de calor bio-inert Quick Connect) |
|
|
0890-1763 (Capillary PEEK 0.18 mm x 1.5 m) and 5063-6591 (PEEK Fittings 10/PK) | Column/MCT Valve | Detector |
5062-8535 (Waste accessory kit (Flow Cell to waste)) | VWD | Waste |
5062-2462 (Tube PTFE 0.7 mm x 5 m, 1.6 mm od) | DAD/FLD | Waste |
G5664-68712 (Analytical tubing kit 0.25 mm i.d. PTFE-ESD) | Detector | Fraction Collector |
p/n | From | To |
|---|---|---|
G7120-60007 (Conjunto da parte superior da garrafa, longo (1730 mm)) | Solvent Bottle | Infinity III Pump |
5500-1419 (Capillary MP35N 0.17 mm x 500 mm, SI/SI) | Pump | Multisampler |
5500-1279 (Capillary MP35N 0.12 mm x 500 mm SI/SI) | Multisampler | MCT |
5500-1578 (Capilar Quick Connect MP35N 0,12 mm x 105 mm) | MCT Heat Exchanger | Column |
5500-1596 (Capilar Quick Turn MP35N 0,12 mm x 280 mm) | Column/MCT Valve | Detector (DAD) |
5500-1598 (Quick Turn Capillary MP35N 0.12 mm x 500 mm) | Column/MCT Valve | Detector (VWD) |
5062-8535 (Waste accessory kit (Flow Cell to waste)) | VWD | Waste |
5062-2462 (Tube PTFE 0.7 mm x 5 m, 1.6 mm od) | DAD/FLD | Waste |
G5664-68712 (Analytical tubing kit 0.25 mm i.d. PTFE-ESD) | Detector | Fraction Collector |
For correct installation of capillary connections it's important to choose the correct fittings, see Syntax for Capillary Description.
Selecione uma porca longa o suficiente para o encaixe que você irá usar.
Deslize os componentes de anilha após a porca. Aperte manualmente o conjunto enquanto garante que a tubulação esteja totalmente colocada no fundo do encaixe de extremidade.
Use a stable port installed to the module to gently tighten the fitting facing to the module. Or use the column to tighten the fitting facing to the column. This measure forces the ferrule to seat onto the tubing or capillary.
NOTA
Do not overtighten. Over-tightening will shorten the lifetime of the fitting.
Afrouxe a porca e verifique se a anilha está devidamente posicionada na tubulação ou tubo capilar.
NOTA
The first time that the Swagelok fitting is used on a column or an injection valve, the position of the ferrule is permanently set. If changing from a column or an injection valve to another, the fitting may leak or decrease the quality of the separation by contributing to band broadening.
For Bio and Bio-Inert Systems, the Swagelok instructions do not apply.