Type | Specification | Comments |
---|---|---|
Weight | 19 kg (41.9 lbs) | w/o sample thermostat |
Dimensions (height × width × depth) | 320 x 396 x 468 mm (12.8 x 15.6 x 18.4 inches) |
|
Line voltage | 100–240 V~, ±10% | Wide-ranging capability |
Line frequency | 50 or 60 Hz, ±5% |
|
Power consumption | 350 VA, 350 W, 1195 BTU/h |
|
Ambient operating temperature | 4–40 °C (39–104 °F); without sample thermostat up to 55 °C (131 °F) |
|
Ambient non-operating temperature | -40–70 °C (-40–158 °F) |
|
Humidity | < 95% r.h. at 40 °C (104 °F)SampleThermostatIncluded | Non-condensing |
Operating altitude | Up to 3000 m (9842 ft) |
|
Safety standards: IEC, EN, CSA, UL | Overvoltage category II, Pollution degree 2 | For indoor use only |
ISM Classification | ISM Group 1 Class B | According to CISPR 11 |
Permitted solvents | Boiling point ≥ 56 °C (133 °F) Auto-ignition temperature ≥ 200 °C (392 °F) |
|
[1]If a sample thermostat is included the upper value for humidity can be reduced. Please check your lab conditions to stay beyond dew point values for non–condensing operation.
Type | Specification | Comments |
---|---|---|
Designed for use with Agilent InfinityLab Assist | Intuitive User Interface, Automated Workflows, Predictive Maintenance & Assisted Troubleshooting | |
Injection range | 0.1 – 100 µL in 0.1 µL increments with 100 µL up to 60 MPa 0.1 – 900 µL in 0.1 µL increments with 900 µL up to 40 MPa | Up to 1800 µL with multiple draw (hardware modification required) Requires 900 µL analytical head |
Injection precision | < 1 % RSD of peak areas from 1 - 5 µL < 0.25 % RSD of peak areas from 5 µL to 100 µL | Measured caffeine |
Injection linearity | R² > 0.9999 |
|
Injection accuracy | < ± 1 % |
|
Pressure range | 0 – 60 MPa (0 – 600 bar, 0 – 8702 psi) 0 – 40 MPa (0 – 400 bar, 0 – 5801 psi) |
For 900 µL analytical head |
Sample viscosity range | 0.2 – 5.0 cP |
|
Sample capacity | 132 x 2 mL vial (two trays default) 100 x 2 mL vial (two classic trays optional) 36 x 6 mL vials (two trays optional) |
|
Carryover | < 0.004 % (40 ppm) with needle wash | Sample: Chlorhexidine |
Injection cycle time | 18 s for draw speed 200 µL/min Ejection speed: 200 µL/min Injection volume: 1 µL |
|
Minimum sample volume | 1 µL from 5 µL sample in 100 µL microvial, or 1 µL from 10 µL sample in 300 µL microvial. | Needle height offset has to be adapted to ensure that needle doesn’t touch vial bottom. Default needle height = 0 equates to 2 mm above the vial bottom. |
Instrument Control | LC & CE Drivers A.02.12 or above Instrument Control Framework (ICF) A.02.03 or above Lab Advisor B.02.07 or above InfinityLab Assist (G7180A) with firmware D.07.40 or above Instant Pilot (G4208A) with firmware B.02.19 or above | For details about supported software versions refer to the compatibility matrix of your version of the LC & CE Drivers |
Communication | Controller Area Network (CAN),Local Area Network (LAN) ERI: ready, start, stop and shut-down signals |
|
Maintenance and safety-related features | Extensive diagnostics, error detection and display with Agilent InfinityLab Assist or with Agilent Lab Advisor software. Leak detection, safe leak handling, leak output signal for shutdown of pumping system, and low voltages in major maintenance areas. |
|
GLP features | Early maintenance feedback (EMF) for continuous tracking of instrument usage with user-settable limits and feedback messages. Electronic records of maintenance and errors. |
|
Housing | All materials recyclable. |
|