Type | Specification | Comments |
---|---|---|
Weight | 11 kg (24.3 lbs) |
|
Dimensions (height × width × depth) | 140 x 396 x 436 mm (5.5 x 15.6 x 17.2 inches) |
|
Line voltage | 100–240 V~, ±10% | Wide-ranging capability |
Line frequency | 50 or 60 Hz, ±5% |
|
Power consumption | 80 VA, 70 W |
|
Ambient operating temperature | 4–55 °C (39–131 °F) |
|
Ambient non-operating temperature | -40–70 °C (-40–158 °F) |
|
Humidity | < 95% r.h. at 40 °C (104 °F) | Non-condensing |
Operating altitude | Up to 3000 m (9842 ft) |
|
Safety standards: IEC, EN, CSA, UL | Overvoltage category II, Pollution degree 2 | For indoor use only |
ISM classification | ISM Group 1 Class B | According to CISPR 11 |
Type | Specification |
---|---|
Detection type | Double-beam photometer |
Designed for use with Agilent InfinityLab Assist | Intuitive User Interface, Automated Workflows, Predictive Maintenance & Assisted Troubleshooting |
Light source | Deuterium lamp |
Number of signals | Single and dual wavelength detection |
Maximum data rate | 240 Hz (single wavelength detection) 2.5 Hz (dual wavelength detection) |
Short term signal noise (ASTM) | < ± 0.15·10-5 AU, at 230 nm (single wavelength detection) < ± 0.80·10-5 AU, at 230 nm and 254 nm (dual wavelength detection) |
Drift | < 1·10-4 AU/h, at 230 nm |
Linear absorbance range | > 2.5 AU upper limit |
Wavelength range | 190 – 600 nm |
Wavelength accuracy | ± 1 nm, self-calibration with deuterium lines, verification with holmium oxide filter |
Wavelength precision | < ± 0.1 nm |
Slit width | 6.5 nm typical over whole wavelength range |
Time programmable | Wavelength, polarity, peak width, lamp on/off |
Flow cells | Standard: 14 µL volume, 10 mm cell path length and 40 bar (580 psi) pressure maximum Micro: 2 µL volume, 3 mm cell path length and 120 bar (1760 psi) pressure maximum Semi-micro: 5 µL volume, 6 mm cell path length and 40 bar (580 psi) pressure maximum Standard Bio: 14 µL volume, 10 mm cell path length and 40 bar (580 psi) pressure maximum Micro Bio: 2 µL volume, 3 mm cell path length and 120 bar (1760 psi) pressure maximum Preparative SST: 4 µL volume, 3 mm cell path length and 120 bar (1760 psi) pressure maximum Preparative Quartz: 4 µL volume, 3 mm cell path length and 50 bar (725 psi) pressure maximum Preparative Quartz: 0.3 mm cell path length and 50 bar (725 psi) pressure maximum Preparative Quartz: 0.06 mm cell path length and 50 bar (725 psi) pressure maximum High pressure: 14 µL volume, 10 mm cell path length and 400 bar (5800 psi) pressure maximum |
Spectral tools | Stop-flow wavelength scan |
Analog output | Recorder/Integrator 100 mV or 1 V, 1 output |
Instrument Control | LC and CE Drivers A.02.11 or above Instrument Control Framework (ICF) A.02.04 or above Lab Advisor B.02.06 or above InfinityLab Assist (G7180A) with firmware D.07.40 or above Agilent Instant Pilot (G4208A) B.02.19 or above For details about supported software versions refer to the compatibility matrix of your version of the LC and CE Drivers |
Communication | LAN, Controller Area Network (CAN), USB Extended Remote Interface: ready, start, stop and shut-down signals |
GLP | Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user settable limits and feedback messages. Electronic records of maintenance and errors. RFID for electronics records of flow cell and UV lamp conditions (path length, volume, product number, serial number, test passed, and usage). Verification of wavelength accuracy with built-in holmium oxide filter. |
Safety and maintenance | Extensive diagnostics, error detection and display through Agilent Instant Pilot and Agilent Lab Advisor software. Leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. Tracking of flow cells and lamps with RFID (radio frequency identification) tags. |
Housing | All materials recyclable. |
Others | Second generation of Electronic temperature control (ETC) for the complete optical unit. |
base-id: 5725582731
id: 36028802744546699